4. Where possible, mount the Detector in the
corner of the room so that the logical path of an
intruder would cut across the fan detection
pattern. PIR Detectors respond more effectively
to movement across the device than to
movement directly towards it.
5. Do not position the Detector in a position where
it is subject to excessive vibration.
6. Ensure that the position selected for the PIR
Detector is within effective range of the Siren.
7. Do not fix the PIR Detector onto or very close
to metalwork (i.e. radiators, water pipes, etc) as
this could affect the radio range of the device.
Note: When the system is Armed, pets should not
be allowed into an area protected by a PIR Detector
as their movement could be detected and trigger
an alarm.
INSTALLING AND CONFIGURING THE
PIR DETECTORS
1. Undo and remove the fixing screw from the
bottom edge of the PIR Detector, (keep the
screw safe for later). Carefully pull the bottom
edge of the detector away from the rear cover
and then slide down to release the top clips.
2. Carefully drill out the required mounting holes in
the rear cover using a 3mm drill according to
whether the unit is being mounted in a corner or
against a flat wall.
3. Using the rear cover as a template, mark the
positions of the fixing holes on the wall.
4. Fix the rear cover to the wall using the two
18mm No.4 screws and 22mm wall plugs,
(a 5mm hole will be required for the wall plugs).
Do not over-tighten the screws as this may
distort or damage the cover.
Note: The wall plugs supplied with the product
are not suitable for plasterboard walls, if
mounting the Detector onto plasterboard use
appropriate wall plugs.
5. To select the required sensitivity, set switch SW3
as follows:
UP HIGH sensitivity
DOWN LOW sensitivity
Note: The recommended setting is LOW for a
most normal environments, if set to HIGH and
false alarms are experienced change the setting
back to LOW.
13
Rear Cover
Fixing
Screw
Rear Cover
Flat Wall
Mounting
Corner Wall
Mounting
Fixing
Screw
SW2
(Tamper)
SW1
(Test Mode)
S
W
3
S
e
n
s
i
t
i
v
i
t
y
H
i
L
o
w
S
W
1
T
e
s
t
M
o
d
e
S
W
2
SW3
(Sensitivity)
SW3 up
High Sensitivity
SW3
Sensitivity
Hi
Low
SW3 down
Low Sensitivity
SW3
Sensitivity
Hi
Low
Przeglądanie stron 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18 ... 39 40

Komentarze do niniejszej Instrukcji

Brak uwag