INSTALLING AND CONFIGURING
THE SIREN
1. Remove the xing screw from the bottom edge of the
Siren housing and carefully hinge off the front cover.
Hold the mounting plate in position and mark the
positions of the 4 mounting holes. A spirit level placed
on the casing will help ensure you get the unit perfectly
level.
2. Drill four 6mm holes and t the 26mm wall plugs.
3. Fit the two 30mm xing screws in the top holes
leaving approximately 10mm of the screw protruding.
4. Fit the top keyhole slots of the mounting plate over
the screw heads. Remove the mounting plate and
adjust the screws until they form a neat t with the
mounting plate with minimal movement.
5. Secure the mounting plate in position using the two
25mm xing screws in the bottom xing holes.
6. Ensure that the Siren’s main conguration switch on
the LED Indicator board is set to “C.U.” for use with this
alarm system.
7. Undo the three screws holding the DIP Switch Cover
in place and remove the cover (see main diagram
opposite).
8. Under the cover you will nd a series of 9 DIP
switches.
Note: When the Siren is viewed as shown above (Solar
panel at top) the DIP switches are ‘upside down’.
9. DIP switches 1-8 are used to set the House Code
for the Siren and must be set to the same ON/OFF
combination as all other system devices.
10. If required, the maximum length of time that the
Siren will sound for when activated under an alarm
condition may be extended to 3 minutes using DIP
switch 9 as follows:
ON = 3 minutes
OFF = 1 minute
11. The Siren will acknowledge Arm and Disarm signals
from the Remote Control and Keypad by beeping. It
is possible to disable these acknowledgement beeps if
required by removing the jumper link P2 on the circuit
board.
P2 tted = Beep enabled
P2 removed = Beep disabled
12. If for any reason you need to disable the Siren,
remove jumper link P3 on the Circuit board. This
will prevent the Siren from sounding during an
alarm condition. However, the Siren will still beep to
acknowledge signals from the Remote Control and
Keypad, (provided the beep feature is not disabled).
IMPORTANT: The Jumper Link (P3) is small so will
need to be stored in a safe place until you need to
reinstate the Siren alarm.
P3 tted = Siren enabled
P3 removed = Siren disabled
13. To enable the Jamming Detect feature in the Siren
t the jumper link taped to the cover of the Siren control
unit across link pins P1 on the circuit board.
P1 tted = Jamming Detection enabled
P1 removed = Jamming Detection disabled
14. Ret the DIP switch cover and replace the 3 cover
xing screws. Do not over tighten the screws as this
could damage the thread.
POWERING UP THE SIREN
1. Connect the 9V PP3 power-up battery to the
battery clip.
Connect the rechargeable battery to the charging
leads. Connect the Red lead to the Red ( + ) terminal
and the Black lead to the Black ( - ) terminal. Both
indicator LEDs will ash together in a single long ash
to indicate that the unit is operational.







