The Control Unit will acknowledge the signal by
bleeping twice and memorise the ‘House Code’ set
in the Remote Control. The Zone LED’s 1-6 will now
indicate the ‘House Code’ switch setting selected for
each switch 1-6 in the Remote Control as follows:-
‘+’ = LED ‘ON’
‘o’ = LED ‘FLASHING’
‘-’ = LED ‘OFF’
5. Once the ‘House Code’ has been set, press
twice to exit programming mode.
Note: It is possible to manually programme the‘House
Code’ into the Control Unit, if a Remote Control is not
available or not required - Refer to Programmable
Functions - page 15.
SETTING THE CONTROL
UNIT TO TEST MODE
Before installing Magnetic Contact Detectors, Passive
Infra Red Detectors or other accessories you should
set the Control Unit to Test mode. This will help to
ensure that the correct ‘House Code’ is used and to
establish the radio range.
1. Press and hold the button, until the Control
Unit emits 2 bleeps and the Full Arm and Part
Arm LED’s flash.
2. The system is now in Test mode.
3. Now, each time the Control Unit receives a
valid radio signal from a Detector or Remote
Control, the Control Unit will emit 2 two-tone
chimes and the associated Zone LED will flash
for approximately 3 seconds.
To test the radio range of the Control Unit’s receiver,
press and release the Disarm (Blue) button on the
Remote Control from in and around the property and
from all locations where you plan to install the Detectors
and check that the Control Unit acknowledges the
signals by emitting the two-tone chime (and flashing the
Medical Alert (Zone 8) LED for 3 seconds).
The Control Unit should be left in Test mode whilst the
detectors and other accessories are set up and installed.
However, if you wish to exit the Test mode, press and
hold the button until the unit emits 2 bleeps and
the Arm/Part Arm LED’s extinguish.
SYSTEM ZONING
The RE5000 Detectors can be set to operate on any
one of 6 Zones. There is no limit to the number of
Detectors that can be installed on a Zone, although
we recommend that only one Detector is installed per
Zone for ease of alarm verification. Alternatively
where more than 6 Detectors are installed, group all
the Detectors in one area/room on the same Zone.
Zone selection is set on each Detector using the 3
position miniature switches 7 and 8, as follows:-
In addition to a Radio Detection Alarm input on Zone
6, facilities are available on the Control Unit Terminal
block to also hard-wire a normally closed (open on
alarm) circuit on Zone 6. The hard-wired Zone should
be wired across terminals ‘Zone 6’ and ‘GRD’ on the
Control Unit terminal block.
Zone 6 also monitors the Control Unit Tamper Circuits,
ie Control Unit fixing/battery cover Tamper switch and
(where fitted) hard-wired siren tamper return.
Separate Zone inputs are available for Fire Alarm
(Zone 7) and Medical Alert (Zone 8).
These Zones are pre-programmed into the RE5000SD
Smoke Detectors and RE5000MP Medical Alert
Pendant respectively. These devices cannot be
assigned to different Zones.
RE5000S Professional Alarm System 9